Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | 1SAP250600R0001 |
| Input Channels | 8 analog inputs |
| Input Signal Types | Voltage, current, Pt100, Pt1000, Ni1000, Cu50, thermocouple types J, K, N, S, T, resistor |
| Resolution | 16 bits including sign |
| Input Configuration Range | Bipolar/Unipolar: -50mV…+50mV, -500mV…+500mV, -1V…+1V, -5V…+5V, -10V…+10V, 0…+5V, 0…+10V, -20mA…+20mA, 0…20mA, 4…20mA |
| Power Supply Voltage | 24 VDC |
| Current Consumption | 130 mA |
| Galvanic Isolation | Yes |
| Conversion Time | 1 ms (none), 100 ms (50/60Hz) |
| Conversion Accuracy (typical @25°C) | ±0.1% (voltage), ±0.3% (current, resistor) |
| Maximum Cable Length | 100 m |
| Mounting Position | Horizontal or vertical (with derating) |
| Protection | Reverse polarity, overvoltage up to 30V, short circuit |
| Degree of Protection | IP20 |
| Operating Temperature | 0…+60°C horizontal, 0…+40°C vertical |
| Storage/Transport Temperature | -40…+70°C |
| Humidity | Max 95% RH, no condensation |
| Dimensions (W x H x D) | 62 x 76 x 67.5 mm |
| Weight | 0.128 kg |
FAQ
FAQ
Q1: What is the resolution of the ABB AI531 module?
A1: The ABB AI531 offers a 16-bit resolution including sign.
Q2: Does the module support thermocouple inputs?
A2: Yes, it supports thermocouple types J, K, N, S, and T.
Q3: Can the AI531 be mounted vertically?
A3: Yes, it can be mounted vertically with derating (maximum operating temperature reduced to 40°C).
Q4: Is there galvanic isolation between inputs and system?
A4: Yes, the module provides galvanic isolation from internal supply and other modules.
Q5: What protection features does the module have?
A5: The AI531 is protected against reverse polarity, overvoltage up to 30V DC, and short circuit.
Q6: What is the maximum permissible cable length for the inputs?
A6: The maximum recommended cable length is 100 meters.
Q7: What is the typical accuracy of voltage measurements?
A7: The typical voltage measurement accuracy is ±0.1% at 25°C.
Q8: How much does the ABB AI531 weigh?
A8: The module weighs approximately 0.128 kg.