Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | KJ4003X1-BG1 |
| Manufacturer | Emerson |
| Product Series | DeltaV™ VerticalPlus |
| Product Type | 8-Wide VerticalPlus Central Carrier |
| Application | DeltaV Distributed Control System (DCS) |
| Function | Central carrier for VerticalPlus I/O modules, provides LocalBus routing and power distribution |
| LocalBus Power | 12.6 VDC at 15 A |
| Maximum System Extension Length | Up to 6.5 m with LocalBus extenders |
| Operating Temperature | -40°C to +70°C |
| Relative Humidity | 5% to 95% Non-Condensing |
| Shock Resistance | 10 g, ½ sine wave for 11 ms |
| Vibration Resistance | 1 mm peak-to-peak from 2–13.2 Hz; 0.7 g from 13.2–150 Hz |
| Airborne Contaminant Rating | ISA-S71.04-1985 Class G3 |
| Protection Rating | IP20 |
| Hazardous Area Approval | Class I, Division 2 / Zone 2 |
| Mounting Type | Cabinet / Rack Mount |
| Maintenance | No user-serviceable parts |
| Calibration | Not required |
| Dimensions (L × W × H) | Approximately 300 mm × 220 mm × 30 mm |
| Weight | Approximately 0.45 kg |
| Country of Origin | United States |
FAQ
FAQ
Q1: What is the Emerson KJ4003X1-BG1 used for?
It is a central 8-wide carrier for VerticalPlus I/O modules, enabling LocalBus communication and power distribution within DeltaV systems.
Q2: How many I/O modules can it support?
As an 8-wide carrier, it can accommodate multiple VerticalPlus I/O modules, depending on system configuration.
Q3: What are the dimensions of the KJ4003X1-BG1?
The carrier measures approximately 300 mm × 220 mm × 30 mm.
Q4: How much does the KJ4003X1-BG1 weigh?
The weight is approximately 0.45 kg.
Q5: What are the power specifications for the carrier?
It supports LocalBus power at 12.6 VDC with a maximum current of 15 A.
Q6: Can it operate in harsh environments?
Yes, it supports -40°C to +70°C and 5%–95% non-condensing relative humidity.
Q7: Is the KJ4003X1-BG1 suitable for hazardous areas?
Yes, it is certified for Class I Division 2 and Zone 2 hazardous locations.
Q8: Does it require maintenance or calibration?
No maintenance or calibration is required. The carrier contains no user-serviceable components.